Adult BLS Emergency Training Manikin (Wireless)
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Bilateral pupils contrast: normal and mydriasis, simulate pupils state (normal, myosis), the manikin make synchronized changes.
- Carotid pulse: control and simulate artery pulse, weak pulse or strong pulse.
- CPR
- Airway management
- Real AED defibrillation
- Script editing
- Available standalone version and online version
- Supports lateral thigh intramuscular injection
- Supports arm venous injection training
- Can be used with various trauma simulators for learning
- Supports multimedia courseware teaching, and can be connected to projector or Demo system.
MedMod/BLS 100B Adult BLS Emergency Training Manikin (wireless)-CPR+AED
MedMod/BLS 100+ Multi-function BLS emergency simulator(wireless)-CPR+AED+Software+ECG+Endotracheal intubation
MedMod/BLS100G Adult BLS Comprehensive emergency team and examination system(Online)-computer+ Four Simulators
Adult CPR Training Manikin (Bluetooth Wireless)
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Item No. | Bluetooth control box | PAD | Result Print | Remote control |
MedMod/CPR100B | + | + | + | |
MedMod/CPR100W | + | + | ||
MedMod/CPR100W+ | + | + | + | + |
Features:
- Accurate anatomical features, realistic feeling, natural complexion, and perfect appearance
- Manikin automatically connects to the electronic monitor via bluetooth
- Manikin vital signs:
- Initial state: manikin’s pupil mydriasis and no carotid pulse
- After successful rescue: manikin’s pupil recover, and carotid pulse begin self-pulsation
- Manikin’s left shoulder supports consciousness judgement, and the result can be printed on the report after operation
- Simulate airway opening, and the relative green light on the monitor will be triggered once the airway is open.
- CPR operating modes: CPR Training, CPR Popularization and CPR Assessment:
- Electronic monitoring: the electronic lights monitor the airway opening, compression sites (including one correct position and four wrong positions), times of correct and wrong artificial respiration and external chest compression.
- Bar code shows the volume of insufflation: correct value should be 500 - 600ml.
- insufficient blowing, the bar code is yellow,
- proper blowing, the bar code is green,
- excessive blowing, the bar code is red.
Bar code shows the compression depth: correct value should be 5cm - 6cm.- Insufficient compression depth, the bar code is yellow,
- proper compression depth, the bar code is green,
- excessive compression depth, the bar code is red.
- English voices prompts during the whole process and the volume is adjustable.
- Compression frequency: 100-120 times/minute
- Remote control can be used to reset, playback and simulate emergency call, pulse check, forerign body removal and breathing judgement, etc.
- Power state: 220V external power source can be used for both manikin and electronic monitor.