AED Simulator

Features:

  1. Simulate AED workflow during first-aid procedure with voice prompts, and it hasn’t high tension shock motion.
  2. Interchangeable voice prompts, in English or in Chinese; and the volume is adjustable.
  3. Pre-set up 9 programs of training mode, each mode is simulated real AED scenarios that meet the latest international training standards, and BLS process can be suspended or continued anytime.
  4. Fault simulation, choosen via remote control, including “Something else touches patient’s body during defibrillation”, “wrong position of electrode pad”, “no need of defibrillation”, “need difibrillation”, “machine error” and “battery low”.
  5. Can be used with manikins in any code and produced by any factory.

Child CPR Manikin (Wireless)

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Features:

  • External chest compression with alarm warning
    1. Child compression depth: at least 1/3 times of thoracic anteroposterior diameter, about 5cm;
    2. Indicator light and alarm warning will be triggered if compression is incorrect.
  • Simulate standard airway opening
  • Artificial mouth to mouth (insufflation) respiration with alarm warning;
    • indicator light and alarm for blow-in tidal volume “<150ml~200ml<”;
    • indicator light for tidal volume “150ml~200ml” (correct);
    • If blowing too fast or too much, the indicator light in the stomach will be on with alarm warning;
  • Operating period: Ratio of compression and respiration is 30:2/singe person or 15:2/ two persons, 5 cycles of CPR operation need to be completed.
  • Operating frequency: the newest international standard: at least 100-120 times/min.
  • Operating mode: Training
  • Carotid pulse reaction: manually squeeze the bulb to simulate the carotid pulse
  • Working condition: adopts 220V external power source, or use 4 pcs 1# battery for field training.
Item No. Bluetooth control box PAD Result print Remote control
MedMod/CPR200B +   + +
MedMod/CPR200W   + +  
MedMod/CPR200W+ + + + +

Infant CPR Training Manikin (Wireless)

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Features:

  • Chest external compression with alarm warning
  • Simulate standard airway opening
  • Artificial mouth to mouth respiration (insufflations) with alarm warning
  • Operating period: Ratio of compression and respiration is 30:2/singe person or 15:2/ two persons, 5 cycles of CPR operation need to be completed.
  • Operating frequency: the newest international standard: at least 100-120 times/min.
  • Operating mode: Training
  • Brachial artery reaction: manually squeeze the bulb to simulate the brachial artery pulse.
  • Working condition: adopts 220V external power source, or use 4 pcs 1# battery for field training.
Item No. Bluetooth control box PAD Result print Remote control
MedMod/CPR300B +   + +
MedMod/CPR300W   + +  
MedMod/CPR300W+ + + + +

Price: xx zł

MEDMOD

Fantomy, które zniosą wszystko.

Kim jesteśmy?

Działamy na rynku fantomów od 2008 roku, Fantomy są nasza pasją, posiadamy unikalna wiedzę na temat swoich produktów oraz tych konkurencyjnych. Sprzedajemy tylko sprawdzone podczas ćwiczeń modele lub te które poznaliśmy osobiście podczas targów medycznych w Dusseldorfie, Poznaniu, Shanghaju czy Hong Kongu. Korzystamy z informacji na temat modeli bezpośrednio od producentów. Dokonujemy także zakupów bezpośrednich na różnych rynkach. Prowadzimy consulting którego celem jest odpowiedni dobór modeli do potrzeb przy zachowaniu kosztów zakupu na odpowiednim poziomie dla klienta. Nasza marka MEDMOD na stałe zagościła w Polsce i jest wspierana poprzez profesjonalny serwis, doradztwo oraz krótkie terminy dostawy wybranych towarów. Zanim kupisz gdzieś coś – zapytaj nas o opinię – może się ona przydać. Zapraszamy do kontaktu -- @@@

Dlaczego my?

  • znamy rynek
  • znamy produkty
  • fantomy to nasza pasja
  • optymalizujemy wydatki naszych klientów
  • pełny zakres wsparcia posprzedażowego
  • szybkie terminy realizacji
  • elastyczność i szybkie decyzje zakupowe oraz rozwiązania logistyczne

Artykuły w promocji


O nas

Szukaj

Kontakt

Skontaktuj się z nami po więcej informacji:

Adres:

ul. Poleska 21

40-733 Katowice

tel. 881 256 600

kontakt@fantom-medmod.eu

Europejskie Fundusze Strukturalne
Tomasz Biliński dla MedMod © 2017