Limbs Fracture First-aid External Fixation Simulation Standardized Patient
Features:
- Simulates head trauma and limbs closed fracture, students can be familiar with symptoms of malformation, bony crepitus and abnormal motion and so on, and they can make diagnosis and treatment.
- Master the operating skills of wounds rinsing, disinfection, binding up, restoration, fracture fixation and transport, which has great clinical meaning for surgical trauma first-aid skills training.
- Trauma includes radius and ulna closed fractures (upper forearm), Tibia and fibula closed fractures trauma (lower limbs), and thigh compound trauma. The end of fracture is touchable, fracture-angle abnormality, and comes with feeling of bone friction.
- Mandible trauma modules: open jaw trauma modules, and wound managerment can be done for the jaw.
- Basic nursing function: I.V. Injection, urethral catheterization, etc.
- All types of brace can be used with this manikin.
- Can be widely used for emergency teaching demonstration and actual practice.
Price: xx zł
Spinal Injury Transport Simulation Standardized Patient
Features:
- Full body manikin with injuries at neck and spine, which can be used to examine how to transport neck fracture patients and spinal injury patients.
- Voice prompts for incorrect positions when neck bows forward, leans backward and turn to left and right; voice prompts for incorrect positions during waist anteflexion and rear extension.
- Voice prompts for wrong operation, and it will disappear when the manikin is placed correctly.
- Pupils: one normal and the other mydriasis for contrast teaching demonstration
- Supports trachea cannula and tracheotomy care.
- Adopts straight moving with several persons. Avoid single person embacing the chest and moving alone in case of second spinal cord injury.
- Equiped with several sensors, voice prompts will be activated when the transport method is wrong.
- Supports multiple nursing skills, e.g. Nasal feeding, ileostomy and colonstomy care, stoma irrigation, urethral catheterization, and deltoids injection.
- Working condition: use DC 12V external power or rechargeable lithium battery.
Price: xx zł
Trauma Sumulators Accessories
Features:
- Facial burn: 1, 2, 3 degree
- Laceration in forehead
- The wound in jaw
- Opened clavicular fracture and contusion wound on the chest
- The wound in abdomen with small intestine evisceration
- Opened humerus fracture of right upper arm
- Opened fracture of right hand (including parenchyma laceration)
- Gun wound in the right palm
- Opened fracture of right thighbone
- Compound femur fracture of left thigh
- Metal pricking wound in right thigh
- Opened tibia fracture of right leg
- Opened fracture of right foot with truncating trauma on small phalanx
- Burns in left forearm: 1, 2, 3 degree
- Truncating trauma on left thigh
- Closed tibia fracture of right leg and contusion wounds in left ankle and foot
Price: xx zł
Trauma Simulators
Features:
- Bone tissue exposure
- Simulate all kinds of trauma of body, burned skin is replaceable.
- Simulate rinsing, disinfection, hemostasis, dressing, fixation and transportation for wound parts.
- Simulate open fracture and breakage in different body positions for management.
- Trauma care: disinfection, dressing change, hemostasis and binding up.
- Advanced trauma modules to come with,
- Facial burn: 1, 2, 3 degree
- Laceration in forehead
- Gun wound in the left palm
- Opened fracture of right thighbone
- The wound in jaw
- Compound femur fracture of left thigh
- Opened clavicular fracture and contusion wound on the chest
- Metal pricking wound in right thigh
- Opened tibia fracture of right leg
- The wound in abdomen with small intestine evisceration
- Opened fracture of right foot with truncating trauma on small phalanx
- Opened humerus fracture of right upper arm
- Burns in right forearm: 1, 2, 3 degree
- Opened fracture of right hand with parenchyma laceration
- Truncating trauma of leg thigh
Price: xx zł
Trauma Limb
Feature:
- Upper limbs and lower limbs trauma models;
- Can be used as accessories, and can be connected to the CPR manikins.
Price: xx zł
High SimulationTrauma Evaluation Modules
Feature:
Fragment wound inlet, mild contusion, spider bites, shotgun wound outlet, shotgun wound inlet, military gun wound inlet, penetrating wound, sabre wound, moderate electric burning, moderate contusion, second-degree burn; third-degree burn, military gun outlet, serious electric burning, fragment wound outlet, scalp contusion, crus degloving injury, open fracture, knife wound, and intestine exposed wound, etc.
Price: xx zł
Half-body CPR Training Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
The product can operate adult Heimlich maneuver.
The simulate manikin is designed according to the anatomy and physiological characteristics and fit for first aid for foreign body in the airway.
Features:
- Simulation of normal airway obstruction
- Provide CPR operation practice ; simulation of airway opening and chest compression
- Simulation of the chest expansion when the airway is empty
- Simulation of the suffocation, foreign body obstruction in airway
- Can operate adult Heimlich maneuver
- Simulation of Carotid pulse
- Individual MOUTH/NOSE piece. replaceable; the manikin comes with 5 pcs MOUTH/NOSE piece;
Item No. | CPR | Obstruction | Control box |
MedMod/CPR-017A | + | + | |
MedMod/CPR-017B | + | ||
MedMod/CPR-018A | + | + | + |
MedMod/CPR-018B | + | + |
Price: xx zł
Child CPR Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Simulate standard open airway
- External breast compression: display device and alarm device
- Indicator light display of correct and wrong compression; alarm of wrong compression
- Intensity display of correct (2-3 cm) and wrong (<2cm or >3cm) compression; alarm of wrong compression
- Artificial respiration (inhalation): display device and alarm device
- Inhalation <150-200ml or > 200ml, wrong indicator light display and alarm prompting; Inhalation between 150-200ml right indicator light display
- Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting
- Ratio of compression and artificial respiratory: 30:2 (one person) or 15:2 (two persons)
- Operating cycle: one cycle includes five times of 30:2 or 15:2 ratio of compression and artificial respiration
- Operation frequency: at least 100-120 times per minute
- Operation methods: exercise operation
- Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse
- Working conditions: Input power is 110-240V
Price: xx zł
Infant Obstruction Manikin
Features:
- Artificial respiration and external chest compression
- Simulation of natural airway, chest expand when airway opened
- Airway opening and chest compression
- Accurate anatomy, proportion of the standard live baby design
- Simulation of body airway obstruction.
Price: xx zł
Infant CPR Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Simulating standard open airway
- Manually external breast compression with finger(s)
- Respiration: during mouth-to-mouth & mouth-to-nose artificial respiration, chest rise can be seen
- Operating period: one period includes five cycles of CPR according to ratio of compression and artificial respiration
(30:2/single or 15:2/double) - Compression frequency: 100-120 times per minute
- Compression depth: it should be 1/3 of chest anteroposterior diameter at least, about 4cm.
- Pinch the pressure ball by hand to simulate brachial artery pulse
- Supports colostomy care
- Simulates abdominal suture and supports wound care
- Working condition: Input power is 110-240V
Price: xx zł