AED Simulator

Features:

  1. Simulate AED workflow during first-aid procedure with voice prompts, and it hasn’t high tension shock motion.
  2. Interchangeable voice prompts, in English or in Chinese; and the volume is adjustable.
  3. Pre-set up 9 programs of training mode, each mode is simulated real AED scenarios that meet the latest international training standards, and BLS process can be suspended or continued anytime.
  4. Fault simulation, choosen via remote control, including “Something else touches patient’s body during defibrillation”, “wrong position of electrode pad”, “no need of defibrillation”, “need difibrillation”, “machine error” and “battery low”.
  5. Can be used with manikins in any code and produced by any factory.

Child CPR Manikin (Wireless)

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Features:

  • External chest compression with alarm warning
    1. Child compression depth: at least 1/3 times of thoracic anteroposterior diameter, about 5cm;
    2. Indicator light and alarm warning will be triggered if compression is incorrect.
  • Simulate standard airway opening
  • Artificial mouth to mouth (insufflation) respiration with alarm warning;
    • indicator light and alarm for blow-in tidal volume “<150ml~200ml<”;
    • indicator light for tidal volume “150ml~200ml” (correct);
    • If blowing too fast or too much, the indicator light in the stomach will be on with alarm warning;
  • Operating period: Ratio of compression and respiration is 30:2/singe person or 15:2/ two persons, 5 cycles of CPR operation need to be completed.
  • Operating frequency: the newest international standard: at least 100-120 times/min.
  • Operating mode: Training
  • Carotid pulse reaction: manually squeeze the bulb to simulate the carotid pulse
  • Working condition: adopts 220V external power source, or use 4 pcs 1# battery for field training.
Item No. Bluetooth control box PAD Result print Remote control
MedMod/CPR200B +   + +
MedMod/CPR200W   + +  
MedMod/CPR200W+ + + + +

Infant CPR Training Manikin (Wireless)

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Features:

  • Chest external compression with alarm warning
  • Simulate standard airway opening
  • Artificial mouth to mouth respiration (insufflations) with alarm warning
  • Operating period: Ratio of compression and respiration is 30:2/singe person or 15:2/ two persons, 5 cycles of CPR operation need to be completed.
  • Operating frequency: the newest international standard: at least 100-120 times/min.
  • Operating mode: Training
  • Brachial artery reaction: manually squeeze the bulb to simulate the brachial artery pulse.
  • Working condition: adopts 220V external power source, or use 4 pcs 1# battery for field training.
Item No. Bluetooth control box PAD Result print Remote control
MedMod/CPR300B +   + +
MedMod/CPR300W   + +  
MedMod/CPR300W+ + + + +

Price: xx zł

Half Body CPR Training Combination

Features:

  1. Simulate standard open airway
  2. External breast compression, intensity display of correct (at least 5cm):
    • Buzzing sound of correct compression intensity
    • Alarming sound of wrong compression intensity
  3. Artificial respiration (inhalation): the volume of inhalation is observed through observing the wave of breast;
    (tidal volume≦500ml/600ml-1000ml≦)
  4. Operation methods: exercise operation

Price: xx zł

Half Body CPR Training Manikin

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Features

  1. Simulate standard open airway
  2. Support training in artificial respiration and external chest compression
  3. Compression Frequency: 100-120 times/minute
  4. External breast compression, intensity display of correct (5cm-6cm):
    1. The yellow indicator light display of correct compression position
    2. Buzzing sound of correct compression intensity, the green indicator light display
    3. Alarming sound of wrong compression intensity, the red indicator light display
  5. The inflated tidal volume can be observed by the chest rise, commonly it should be 500-600ml.
  6. Power supply: power adapter

Price: xx zł

Half Body CPR Training Manikin

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Features:

  1. Simulate standard open airway
  2. Support training in artificial respiration and external chest compression
  3. Compression Frequency: 100-120 times/minute, take the “tick” sound as the sign, and the compression depth should be 5cm - 6cm.
  4. The inflated tidal volume can be observed by the chest rise, commonly it should be 500-600ml.
  5. Power supply: power adapter

Price: xx zł

Half Body CPR Training Manikin

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Features:

  1. Pupil demonstration: one mydriasis and the other normal
  2. Simulate standard open airway
  3. Simulate free movements of upper limbs
  4. External chest compression: display device and alarm device
  5. Artificial respiration (Inhalation): display device and alarm device
  6. Operating period: Ratio of compression and artificial respiration:
    30:2 (one or two persons), complete 5 cycles.
  7. Compression frequency: 100 - 120 times/minute
  8. Compression depth: 5-6cm
  9. Squeeze the bulb manually to simulate carotid pulse
  10. Working conditions: adopts 220V external power source

Price: xx zł

CPR Training Manikin

Implement standard: AH A (American Heart Association) 2015 guideline for CPR and ECC

Features:

  1. Pupil demonstration: one mydriasis and the other normal
  2. Simulate standard open airway
  3. Simulate free movements of upper limbs
  4. External chest compression: display device and alarm device
  5. Artificial respiration (Inhalation): display device and alarm device
  6. Operating period: Ratio of compression and artificial respiration: 30:2 (one or two persons), complete 5 cycles.
  7. Compression frequency: 100 - 120 times/minute
  8. Compression depth: 5-6cm
  9. Squeeze the bulb manually to simulate carotid pulse
  10. Working conditions: adopts 220V external power source

Price: xx zł

CPR Training Manikin

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Features:

  1. Accurate anatomical features, realistic feeling, natural complexion, and perfect appearance
  2. Manikin connects to the electronic monitor via compression and ventilation duct.
  3. Manikin vital signs:
    1. Initial state: manikin’s pupil mydriasis and no carotid pulse
    2. After successful rescue: manikin’s pupil recover, and carotid pulse begin self-pulsation
  4. Manikin’s left shoulder supports consciousness judgement, and the result can be printed on the report after operation
  5. Simulate airway opening, and the relative green light on the monitor will be triggered once the airway is open.
  6. CPR operating modes: CPR Training, CPR Popularization and CPR Assessment:
  7. Electronic monitoring: the electronic lights monitor the airway opening, compression sites (including one correct position and four wrong positions), times of correct and wrong artificial respiration and external chest compression.
  8. Bar code shows the volume of insufflation: correct value should be 500 - 600ml.
    1. insufficient blowing, the bar code is yellow,
    2. proper blowing, the bar code is green,
    3. excessive blowing, the bar code is red.
      Bar code shows the compression depth: correct value should be 5cm - 6cm.
      1. Insufficient compression depth, the bar code is yellow,
      2. proper compression depth, the bar code is green,
      3. excessive compression depth, the bar code is red.
  9. English voices prompts during the whole process and the volume is adjustable.
  10. Compression frequency: 100-120 times/minute
  11. Remote control can be used to reset, playback and simulate emergency call, pulse check, forerign body removal and breathing judgement, etc.
  12. Power state: adopts 220V external power source, which can be used for both manikin and electronic monitor.

Price: xx zł

Adult BLS Emergency Training Manikin (Wireless)

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Features:

  • Bilateral pupils contrast: normal and mydriasis, simulate pupils state (normal, myosis), the manikin make synchronized changes.
  • Carotid pulse: control and simulate artery pulse, weak pulse or strong pulse.
  • CPR
  • Airway management
  • Real AED defibrillation
  • Script editing
  • Available standalone version and online version
  • Supports lateral thigh intramuscular injection
  • Supports arm venous injection training
  • Can be used with various trauma simulators for learning
  • Supports multimedia courseware teaching, and can be connected to projector or Demo system.

MedMod/BLS 100B Adult BLS Emergency Training Manikin (wireless)-CPR+AED

MedMod/BLS 100+ Multi-function BLS emergency simulator(wireless)-CPR+AED+Software+ECG+Endotracheal intubation

MedMod/BLS100G Adult BLS Comprehensive emergency team and examination system(Online)-computer+ Four Simulators

Adult CPR Training Manikin (Bluetooth Wireless)

Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC

Item No. Bluetooth control box PAD Result Print Remote control
MedMod/CPR100B +   + +
MedMod/CPR100W   + +  
MedMod/CPR100W+ + + + +

Features:

  1. Accurate anatomical features, realistic feeling, natural complexion, and perfect appearance
  2. Manikin automatically connects to the electronic monitor via bluetooth
  3. Manikin vital signs:
    1. Initial state: manikin’s pupil mydriasis and no carotid pulse
    2. After successful rescue: manikin’s pupil recover, and carotid pulse begin self-pulsation
  4. Manikin’s left shoulder supports consciousness judgement, and the result can be printed on the report after operation
  5. Simulate airway opening, and the relative green light on the monitor will be triggered once the airway is open.
  6. CPR operating modes: CPR Training, CPR Popularization and CPR Assessment:
  7. Electronic monitoring: the electronic lights monitor the airway opening, compression sites (including one correct position and four wrong positions), times of correct and wrong artificial respiration and external chest compression.
  8. Bar code shows the volume of insufflation: correct value should be 500 - 600ml.
    1. insufficient blowing, the bar code is yellow,
    2. proper blowing, the bar code is green,
    3. excessive blowing, the bar code is red.
      Bar code shows the compression depth: correct value should be 5cm - 6cm.
      1. Insufficient compression depth, the bar code is yellow,
      2. proper compression depth, the bar code is green,
      3. excessive compression depth, the bar code is red.
  9. English voices prompts during the whole process and the volume is adjustable.
  10. Compression frequency: 100-120 times/minute
  11. Remote control can be used to reset, playback and simulate emergency call, pulse check, forerign body removal and breathing judgement, etc.
  12. Power state: 220V external power source can be used for both manikin and electronic monitor.

 

Price: xx zł

Adult ALS Emergency Training System (Wireless)

Complying with AHA (American Heart Association) 2015 guideline for CPR, it provides ALS (Advanced Life Support) comprehensive training in first aid skills. The system consists of full-body manikin and a LCD with big screen. It provides a simple and practical ALS training tool.

Features:

  1. Vital signs simulation: pupil change and carotid arterial pulse.
  2. Arm injection training practice.
  3. Airway management: standard nasal and oral intubation, tracheotomy intubation, supporting to head tilt and Jaw thrust, audible feedback if pressure exerted on the teeth during intubation.
  4. CPR: instantaneous displaying graphics of data, statistic report, and sound directions related to CPR, voice prompts of correct and wrong operation, data statistic, result printing, available of training and exam mode.
  5. AED: automatically external defibrillation machine (only for training use), providing electrode pad and electrode button.
  6. Physical therapy: ECG monitoring via defibrillation connectors, the maximal energy of defibrillation is 360J; the frequency of external pacemaker is set to 60 times/min, and the current threshold is 40mA.
  7. Manikin’s bare joint can rotate left and right, basically the same with the real human body size, and do foot care operations.
  8. Manikin has interchangeable male and female external genitalia, can do catheterization operation training, bladder simulator is equipped inside, simulated urine can be injected into; if the operation is successful the simulated urine would flow out.

Standard components:

  1. Full body manikin (1)
  2. ALS monitor (1)
  3. ALS converter (1)
  4. Aluminum & plastic box (1)
  5. CPR operation pad (1)
  6. Exchangeable lung bag (5)
  7. CPR face shield sheet (50pcs/box)
  8. Temperature sensing print paper (2 roll)
  9. Airway intubation parts (1)
  10. Guide manual (1)

Price: xx zł

Baby Jack Newborn Resuscitation Simulator

Features:

  • CPR: supports BVM to mouth, obvious chest rise; and external chest compression;
  • Simulates airway opening
  • Umbilical cord cutting and nursing
  • Equipped with pressure bulbs, manually squeeze the red one, there will be umbilical artery pulse; squeeze the green bulb, there will be spontaneous respiration.

Price: xx zł

MEDMOD

Fantomy, które zniosą wszystko.

Kim jesteśmy?

Działamy na rynku fantomów od 2008 roku, Fantomy są nasza pasją, posiadamy unikalna wiedzę na temat swoich produktów oraz tych konkurencyjnych. Sprzedajemy tylko sprawdzone podczas ćwiczeń modele lub te które poznaliśmy osobiście podczas targów medycznych w Dusseldorfie, Poznaniu, Shanghaju czy Hong Kongu. Korzystamy z informacji na temat modeli bezpośrednio od producentów. Dokonujemy także zakupów bezpośrednich na różnych rynkach. Prowadzimy consulting którego celem jest odpowiedni dobór modeli do potrzeb przy zachowaniu kosztów zakupu na odpowiednim poziomie dla klienta. Nasza marka MEDMOD na stałe zagościła w Polsce i jest wspierana poprzez profesjonalny serwis, doradztwo oraz krótkie terminy dostawy wybranych towarów. Zanim kupisz gdzieś coś – zapytaj nas o opinię – może się ona przydać. Zapraszamy do kontaktu -- @@@

O nas

Szukaj

Kontakt

Skontaktuj się z nami po więcej informacji:

Adres:

ul. Poleska 21

40-733 Katowice

tel. 881 256 600

kontakt@fantom-medmod.eu

Europejskie Fundusze Strukturalne
Tomasz Biliński dla MedMod © 2017