Ratownictwo medyczne
Half-body CPR Training Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
The product can operate adult Heimlich maneuver.
The simulate manikin is designed according to the anatomy and physiological characteristics and fit for first aid for foreign body in the airway.
Features:
- Simulation of normal airway obstruction
- Provide CPR operation practice ; simulation of airway opening and chest compression
- Simulation of the chest expansion when the airway is empty
- Simulation of the suffocation, foreign body obstruction in airway
- Can operate adult Heimlich maneuver
- Simulation of Carotid pulse
- Individual MOUTH/NOSE piece. replaceable; the manikin comes with 5 pcs MOUTH/NOSE piece;
Item No. | CPR | Obstruction | Control box |
MedMod/CPR-017A | + | + | |
MedMod/CPR-017B | + | ||
MedMod/CPR-018A | + | + | + |
MedMod/CPR-018B | + | + |
Price: xx zł
Child CPR Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Simulate standard open airway
- External breast compression: display device and alarm device
- Indicator light display of correct and wrong compression; alarm of wrong compression
- Intensity display of correct (2-3 cm) and wrong (<2cm or >3cm) compression; alarm of wrong compression
- Artificial respiration (inhalation): display device and alarm device
- Inhalation <150-200ml or > 200ml, wrong indicator light display and alarm prompting; Inhalation between 150-200ml right indicator light display
- Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting
- Ratio of compression and artificial respiratory: 30:2 (one person) or 15:2 (two persons)
- Operating cycle: one cycle includes five times of 30:2 or 15:2 ratio of compression and artificial respiration
- Operation frequency: at least 100-120 times per minute
- Operation methods: exercise operation
- Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse
- Working conditions: Input power is 110-240V
Price: xx zł
Infant Obstruction Manikin
Features:
- Artificial respiration and external chest compression
- Simulation of natural airway, chest expand when airway opened
- Airway opening and chest compression
- Accurate anatomy, proportion of the standard live baby design
- Simulation of body airway obstruction.
Price: xx zł
Infant CPR Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Simulating standard open airway
- Manually external breast compression with finger(s)
- Respiration: during mouth-to-mouth & mouth-to-nose artificial respiration, chest rise can be seen
- Operating period: one period includes five cycles of CPR according to ratio of compression and artificial respiration
(30:2/single or 15:2/double) - Compression frequency: 100-120 times per minute
- Compression depth: it should be 1/3 of chest anteroposterior diameter at least, about 4cm.
- Pinch the pressure ball by hand to simulate brachial artery pulse
- Supports colostomy care
- Simulates abdominal suture and supports wound care
- Working condition: Input power is 110-240V
Price: xx zł
AED Simulator
Features:
- Simulate AED workflow during first-aid procedure with voice prompts, and it hasn’t high tension shock motion.
- Interchangeable voice prompts, in English or in Chinese; and the volume is adjustable.
- Pre-set up 9 programs of training mode, each mode is simulated real AED scenarios that meet the latest international training standards, and BLS process can be suspended or continued anytime.
- Fault simulation, choosen via remote control, including “Something else touches patient’s body during defibrillation”, “wrong position of electrode pad”, “no need of defibrillation”, “need difibrillation”, “machine error” and “battery low”.
- Can be used with manikins in any code and produced by any factory.
Child CPR Manikin (Wireless)
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- External chest compression with alarm warning
- Child compression depth: at least 1/3 times of thoracic anteroposterior diameter, about 5cm;
- Indicator light and alarm warning will be triggered if compression is incorrect.
- Simulate standard airway opening
- Artificial mouth to mouth (insufflation) respiration with alarm warning;
- indicator light and alarm for blow-in tidal volume “<150ml~200ml<”;
- indicator light for tidal volume “150ml~200ml” (correct);
- If blowing too fast or too much, the indicator light in the stomach will be on with alarm warning;
- Operating period: Ratio of compression and respiration is 30:2/singe person or 15:2/ two persons, 5 cycles of CPR operation need to be completed.
- Operating frequency: the newest international standard: at least 100-120 times/min.
- Operating mode: Training
- Carotid pulse reaction: manually squeeze the bulb to simulate the carotid pulse
- Working condition: adopts 220V external power source, or use 4 pcs 1# battery for field training.
Item No. | Bluetooth control box | PAD | Result print | Remote control |
MedMod/CPR200B | + | + | + | |
MedMod/CPR200W | + | + | ||
MedMod/CPR200W+ | + | + | + | + |
Infant CPR Training Manikin (Wireless)
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Chest external compression with alarm warning
- Simulate standard airway opening
- Artificial mouth to mouth respiration (insufflations) with alarm warning
- Operating period: Ratio of compression and respiration is 30:2/singe person or 15:2/ two persons, 5 cycles of CPR operation need to be completed.
- Operating frequency: the newest international standard: at least 100-120 times/min.
- Operating mode: Training
- Brachial artery reaction: manually squeeze the bulb to simulate the brachial artery pulse.
- Working condition: adopts 220V external power source, or use 4 pcs 1# battery for field training.
Item No. | Bluetooth control box | PAD | Result print | Remote control |
MedMod/CPR300B | + | + | + | |
MedMod/CPR300W | + | + | ||
MedMod/CPR300W+ | + | + | + | + |
Price: xx zł
Half Body CPR Training Combination
Features:
- Simulate standard open airway
- External breast compression, intensity display of correct (at least 5cm):
- Buzzing sound of correct compression intensity
- Alarming sound of wrong compression intensity
- Artificial respiration (inhalation): the volume of inhalation is observed through observing the wave of breast;
(tidal volume≦500ml/600ml-1000ml≦) - Operation methods: exercise operation
Price: xx zł
Half Body CPR Training Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features
- Simulate standard open airway
- Support training in artificial respiration and external chest compression
- Compression Frequency: 100-120 times/minute
- External breast compression, intensity display of correct (5cm-6cm):
- The yellow indicator light display of correct compression position
- Buzzing sound of correct compression intensity, the green indicator light display
- Alarming sound of wrong compression intensity, the red indicator light display
- The inflated tidal volume can be observed by the chest rise, commonly it should be 500-600ml.
- Power supply: power adapter
Price: xx zł
Half Body CPR Training Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Pupil demonstration: one mydriasis and the other normal
- Simulate standard open airway
- Simulate free movements of upper limbs
- External chest compression: display device and alarm device
- Artificial respiration (Inhalation): display device and alarm device
- Operating period: Ratio of compression and artificial respiration:
30:2 (one or two persons), complete 5 cycles. - Compression frequency: 100 - 120 times/minute
- Compression depth: 5-6cm
- Squeeze the bulb manually to simulate carotid pulse
- Working conditions: adopts 220V external power source
Price: xx zł
Half Body CPR Training Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Simulate standard open airway
- Support training in artificial respiration and external chest compression
- Compression Frequency: 100-120 times/minute, take the “tick” sound as the sign, and the compression depth should be 5cm - 6cm.
- The inflated tidal volume can be observed by the chest rise, commonly it should be 500-600ml.
- Power supply: power adapter
Price: xx zł
CPR Training Manikin
Implement standard: AH A (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Pupil demonstration: one mydriasis and the other normal
- Simulate standard open airway
- Simulate free movements of upper limbs
- External chest compression: display device and alarm device
- Artificial respiration (Inhalation): display device and alarm device
- Operating period: Ratio of compression and artificial respiration: 30:2 (one or two persons), complete 5 cycles.
- Compression frequency: 100 - 120 times/minute
- Compression depth: 5-6cm
- Squeeze the bulb manually to simulate carotid pulse
- Working conditions: adopts 220V external power source
Price: xx zł
CPR Training Manikin
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Accurate anatomical features, realistic feeling, natural complexion, and perfect appearance
- Manikin connects to the electronic monitor via compression and ventilation duct.
- Manikin vital signs:
- Initial state: manikin’s pupil mydriasis and no carotid pulse
- After successful rescue: manikin’s pupil recover, and carotid pulse begin self-pulsation
- Manikin’s left shoulder supports consciousness judgement, and the result can be printed on the report after operation
- Simulate airway opening, and the relative green light on the monitor will be triggered once the airway is open.
- CPR operating modes: CPR Training, CPR Popularization and CPR Assessment:
- Electronic monitoring: the electronic lights monitor the airway opening, compression sites (including one correct position and four wrong positions), times of correct and wrong artificial respiration and external chest compression.
- Bar code shows the volume of insufflation: correct value should be 500 - 600ml.
- insufficient blowing, the bar code is yellow,
- proper blowing, the bar code is green,
- excessive blowing, the bar code is red.
Bar code shows the compression depth: correct value should be 5cm - 6cm.- Insufficient compression depth, the bar code is yellow,
- proper compression depth, the bar code is green,
- excessive compression depth, the bar code is red.
- English voices prompts during the whole process and the volume is adjustable.
- Compression frequency: 100-120 times/minute
- Remote control can be used to reset, playback and simulate emergency call, pulse check, forerign body removal and breathing judgement, etc.
- Power state: adopts 220V external power source, which can be used for both manikin and electronic monitor.
Price: xx zł
Adult BLS Emergency Training Manikin (Wireless)
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
- Bilateral pupils contrast: normal and mydriasis, simulate pupils state (normal, myosis), the manikin make synchronized changes.
- Carotid pulse: control and simulate artery pulse, weak pulse or strong pulse.
- CPR
- Airway management
- Real AED defibrillation
- Script editing
- Available standalone version and online version
- Supports lateral thigh intramuscular injection
- Supports arm venous injection training
- Can be used with various trauma simulators for learning
- Supports multimedia courseware teaching, and can be connected to projector or Demo system.
MedMod/BLS 100B Adult BLS Emergency Training Manikin (wireless)-CPR+AED
MedMod/BLS 100+ Multi-function BLS emergency simulator(wireless)-CPR+AED+Software+ECG+Endotracheal intubation
MedMod/BLS100G Adult BLS Comprehensive emergency team and examination system(Online)-computer+ Four Simulators
Adult CPR Training Manikin (Bluetooth Wireless)
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Item No. | Bluetooth control box | PAD | Result Print | Remote control |
MedMod/CPR100B | + | + | + | |
MedMod/CPR100W | + | + | ||
MedMod/CPR100W+ | + | + | + | + |
Features:
- Accurate anatomical features, realistic feeling, natural complexion, and perfect appearance
- Manikin automatically connects to the electronic monitor via bluetooth
- Manikin vital signs:
- Initial state: manikin’s pupil mydriasis and no carotid pulse
- After successful rescue: manikin’s pupil recover, and carotid pulse begin self-pulsation
- Manikin’s left shoulder supports consciousness judgement, and the result can be printed on the report after operation
- Simulate airway opening, and the relative green light on the monitor will be triggered once the airway is open.
- CPR operating modes: CPR Training, CPR Popularization and CPR Assessment:
- Electronic monitoring: the electronic lights monitor the airway opening, compression sites (including one correct position and four wrong positions), times of correct and wrong artificial respiration and external chest compression.
- Bar code shows the volume of insufflation: correct value should be 500 - 600ml.
- insufficient blowing, the bar code is yellow,
- proper blowing, the bar code is green,
- excessive blowing, the bar code is red.
Bar code shows the compression depth: correct value should be 5cm - 6cm.- Insufficient compression depth, the bar code is yellow,
- proper compression depth, the bar code is green,
- excessive compression depth, the bar code is red.
- English voices prompts during the whole process and the volume is adjustable.
- Compression frequency: 100-120 times/minute
- Remote control can be used to reset, playback and simulate emergency call, pulse check, forerign body removal and breathing judgement, etc.
- Power state: 220V external power source can be used for both manikin and electronic monitor.
Price: xx zł
Adult ALS Emergency Training System (Wireless)
Complying with AHA (American Heart Association) 2015 guideline for CPR, it provides ALS (Advanced Life Support) comprehensive training in first aid skills. The system consists of full-body manikin and a LCD with big screen. It provides a simple and practical ALS training tool.
Features:
- Vital signs simulation: pupil change and carotid arterial pulse.
- Arm injection training practice.
- Airway management: standard nasal and oral intubation, tracheotomy intubation, supporting to head tilt and Jaw thrust, audible feedback if pressure exerted on the teeth during intubation.
- CPR: instantaneous displaying graphics of data, statistic report, and sound directions related to CPR, voice prompts of correct and wrong operation, data statistic, result printing, available of training and exam mode.
- AED: automatically external defibrillation machine (only for training use), providing electrode pad and electrode button.
- Physical therapy: ECG monitoring via defibrillation connectors, the maximal energy of defibrillation is 360J; the frequency of external pacemaker is set to 60 times/min, and the current threshold is 40mA.
- Manikin’s bare joint can rotate left and right, basically the same with the real human body size, and do foot care operations.
- Manikin has interchangeable male and female external genitalia, can do catheterization operation training, bladder simulator is equipped inside, simulated urine can be injected into; if the operation is successful the simulated urine would flow out.
Standard components:
- Full body manikin (1)
- ALS monitor (1)
- ALS converter (1)
- Aluminum & plastic box (1)
- CPR operation pad (1)
- Exchangeable lung bag (5)
- CPR face shield sheet (50pcs/box)
- Temperature sensing print paper (2 roll)
- Airway intubation parts (1)
- Guide manual (1)
Price: xx zł
Baby Jack Newborn Resuscitation Simulator
Features:
- CPR: supports BVM to mouth, obvious chest rise; and external chest compression;
- Simulates airway opening
- Umbilical cord cutting and nursing
- Equipped with pressure bulbs, manually squeeze the red one, there will be umbilical artery pulse; squeeze the green bulb, there will be spontaneous respiration.
Price: xx zł
Neonatal ACLS Emergency Training System (Wireless)
Features:
★ This sign indicates that the functions can be run only when the manikin is used with the optional accessories
Head and neck:
- Normal, dilated pupil;
- Airway management: realistic mouth, nose, tongue, gum, throat, esophagus, epiglottis, trachea, tracheal ring ; can practice tracheal intubation via mouth or nose, sputum suction; oxygen inhaling; may monitor airway intubation and umbilical vein catheterization, show correct and wrong intubation; there is prompt for wrong tracheal intubation; only right chest rise can be observed due to excessive intubation position;
- Gastric intubation: detect tube position via auscultation; inserting gastric tube for gastrointestinal decompression, nasal feeding, gastric lavage, etc.
Chest and abdomen:
- Pneumothorax puncture extraction, pleural effusion extraction training;
- Auscultation sound: include heart sound, breath sound, bowel sound, of which the normal heart sound and breath sound can be adjusted according to the monitor HR and respiratory rate;
- CPR training: Support multiple ventilation ways: mouth to mouth, mouth to nose, BVM to mouth; can monitor inflation times and frequency, compression time, frequency and depth; judge the ratio of artificial breathing and chest compression;
- ★ Real defibrillation and pacing: Achieve real defibrillation and pacing by using with real defibrillating pacer(prepared by user-self);
- ★ ECG monitoring: Be used with real ECG monitor (prepared by user-self) to realize ECG monitoring;
- ★ Simulative ECG monitoring should be used with multi-parameter simulation of ECG to achieve the function of monitoring ECG;
- ★ Simulate defibrillation and pacing: should be used with simulative defibrillating pacer; can choose defibrillation energy, the max energy is 360J;
Limbs:
- Venous transfusion/puncture, arm veins include and Scalp vein includes.
- Umbilical care: Practice ligature of umbilical cord, umbilical vein catheterization;
- Bone marrow puncture: Effusion of simulative bone marrow prompts proper tibial puncture; can inject into drugs and practice transfusion;
- BP measurement training
Software:
- Vital signs monitoring: spontaneous breath; simulate femoral artery, umbilical artery pulse; heart rate, cardiac rhythm, crying, hiccupping, BP, saturation of blood oxygen, ABP, mixed cyanosis, central cyanosis, peripheral cyanosis, amniotic fluid, muscular tension, convulsion, reflection, spontaneous movement and general paralysis; can perform Apgar score;
- ECG, emergency scenes and cases are available in the system;
- Neonatal ACLS emergency script editor is used to edit neonatal emergency cases and simulate emergency scenes;
- Neonatal ACLS emergency script training software
- Perform PETCO2: confirm tracheal intubation position and monitor the effectiveness of resuscitation operation
Standard components:
- Intelligent ACLS Neonate Manikin
- BP Training Equipment
- Heart and Lung Auscultation Simulator Set
- ECG Generator
- Defibrillator Converter
- BVM, Stethoscope, Laryngoscope, Tracheotomy tube, Infusion set.
- Emergency System Controller
- Medical Air Compressor
Optional accessories:
- Video monitoring equipment
- Computer
- Computer control console
- Stainless steel control console
- Rescue operation station
Price: xx zł
Infant ACLS Emergency Training System (Wireless)
Features:
- Life size infant model with flexible joints and realistic anatomical structures of ribs, lungs, heart, stomach, liver, trachea and esophagus, etc.
- Pupil: normal and mydriasis
- Simulates spontaneous respiration, femoral pulse and umbilical artery pulse; cyanosis changes on infant cheek, lips, hands, legs with different degree, mild or serious.
- CPR:
- External chest compression: The screen will show if compression depth and frequency is correct.
- Head hypsokinesis, eclectronically detect airway opening, provide multiple ventilation ways: mouth to mouth, mouth to nose, BVM, respirator, etc.
- Can be used with simulative defibrillator and pace-maker, the default output energy: 1-360J, and the defibrillation times: 1-3; can be freely set.
- System has prompts for correct or wrong defibrillation.
- ECG varies with each defibrillation, and different waveforms are shown.
- Real and Simulative AED
- Injection: supports arm intravenous injection, and the skin and vessels are replaceable; intramuscular injection: the modules are detachable and replaceable, easy to wash, and can be used for repeated practice.
- Nasal feeding: gastric liquid can be extracted after correct intubation into stomach.
- Urethral catheterization: interchangeable male and female urethral catheterization, simulative urine can be collected after correct operation.
- Nearly one hundred common first-aid medicines for choices, and 12 methods of administration (intracutaneous, subcutaneous, intramuscular, I.V., intravenous drop, intracheal, external use, hypogloeeis, per os, rectum, injection pump, infusion pump); computer will automatically display and make records after correct operation.
- Other software function
- System will give prompts for wrong operations or wrong settings.
- Record, save and print with passwords settings for the whole process, safely and effectively
- Optional network modules: divide into “Teacher’s System” and “Student’s System”, with modules of virtual teacher, class pattern, group pattern, group discussion, teacher monitoring, student demonstration, broadcast teaching, window teaching, phonetic teaching, fast tutorship and whiteboard, etc, which makes it easy to realize the situational teaching and interaction of teachers and students.
Price: xx zł
Strona 2 z 3